Fluke 190M-4 kit with accessories

Fluke 190M-4 4 Channel 200 MHz Medical ScopeMeter

Fluke 190M-2 2 Channel 200 MHz Medical ScopeMeter

$2,895.00
Availability: In stock
SKU
1H343

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

  • Fluke 190M-2 Medical ScopeMeter 2 Channel 200MHz Oscilloscope (BC# 42708-L/T*) 
  • Fluke VPS410-II-B Voltage Probe Set Blue
  • Fluke VPS410-II-R Voltage Probe Set Red
  • (2) Fluke Hard Point Test Leads
  • AC Adapter/Charger
  • USB PC Interface Cable
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

Fluke 190M-2 Portable Handheld Oscilloscope


The 190M: a new generation of medical oscilloscope

The 190M is available with choice of two or four channels and offers an unprecedented level of performance, ruggedness, and portability. With the combined power of a high-performance oscilloscope, multimeter and paperless recorder in an easy-to-use test tool, the 190M is the one test tool you can rely on to tackle just about any troubleshooting task in the field.

To minimize downtime and repair costs, you need to get to the root cause of problems as quickly as possible. The 190M offers a number of unique features to help you quickly set up the scope and diagnose difficult problems like intermittent events, signal fluctuations or drift.

Extend your arsenal of troubleshooting capabilities with the new Fluke Biomedical 190M Medical ScopeMeter portable oscilloscope, designed to meet the demands of field service professionals.


Key Features:
• Two or four electrically-isolated inputs
• Fast sampling rate, up to 2.5 GS/s on two channels simultaneously with up to 400 ps resolution
• Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details (scope mode)
• Dedicated 5000 count digital multimeter in two-channel model
• Quad meter measurements via scope BNC inputs in four channel model
• Connect-and-View™ triggering for intelligent, automatic triggering on fast, slow and even complex signals
• Frequency spectrum using FFT-analysis
• High-resolution, non-interlaced video
• Smart averaging
• ScopeRecord roll mode gives 30,000 points per input channel and capture waveform sample data for up to 48 hours
• TrendPlot, trend measurement readings for up to 22 days
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• Two USB ports make it easy to transfer data to a PC and store unlimited waveforms, screen captures and instrument setups on USB memory devices
• New high-perfomance Li-ion battery technology delivers the longest battery life on the market
• Charge spare battery using optional external battery charger
• Easy-access battery door for quick swaps in the field
• Security slot locks down oscilloscope with Kensington lock while unattended
• Environmentally tested to meet IP-51 and withstand 3 g vibration or 30 g shock


Specifications
Vertical Deflection
Number Of Channels 2
Bandwidth 200MHz
Rise time 1.7ns
Number of scope inputs 2 input channels plus external trigger
Channel architecture All inputs fully insulated from each other and from ground Inputs may be activated in any combination
Input coupling AC or DC, with ground level indicator
Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation
Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth
Normal/invert/variable On each input channel, switched separately
Extended offset Not avalable currently
Input voltage CAT III 1000 V/CAT IV 600 V rated, see general specifications for further details
Vertical resolution 8 bit
Accuracy ± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
Input impedance 1 MΩ ± 1 %/14 pF ± 2 pF
Horizontal
Maximum real-time sample rate (sampled simultaneously) 2.5 GS/s (2ch)
Record length Up to 10,000 samples per channel
Time base range 2 ns/div to 4 s/div
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord™ roll mode (see recorder mode)
Maximum record length 10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecord™ roll mode (see recorder mode)
Timing accuracy ± (0.01 % of reading + 1 pixel)
Glitch capture 8 ns peak detect on each channel (using real time sampling and data compression, at any timebase setting)