Fluke 190M-2 2 Channel 200 MHz Medical ScopeMeter
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 190M-2 Medical ScopeMeter 2 Channel 200MHz Oscilloscope (BC# 42708-L/T*)
- Fluke VPS410-II-B Voltage Probe Set Blue
- Fluke VPS410-II-R Voltage Probe Set Red
- (2) Fluke Hard Point Test Leads
- AC Adapter/Charger
- USB PC Interface Cable
- User Manual On CD-ROM
- Carrying Case (G)
Fluke 190M-2 Portable Handheld Oscilloscope
The 190M: a new generation of medical oscilloscope
The 190M is available with choice of two or four channels and offers an unprecedented level of performance, ruggedness, and portability. With the combined power of a high-performance oscilloscope, multimeter and paperless recorder in an easy-to-use test tool, the 190M is the one test tool you can rely on to tackle just about any troubleshooting task in the field.
To minimize downtime and repair costs, you need to get to the root cause of problems as quickly as possible. The 190M offers a number of unique features to help you quickly set up the scope and diagnose difficult problems like intermittent events, signal fluctuations or drift.
Extend your arsenal of troubleshooting capabilities with the new Fluke Biomedical 190M Medical ScopeMeter portable oscilloscope, designed to meet the demands of field service professionals.
Key Features:
• Two or four electrically-isolated inputs
• Fast sampling rate, up to 2.5 GS/s on two channels simultaneously with up to 400 ps resolution
• Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details (scope mode)
• Dedicated 5000 count digital multimeter in two-channel model
• Quad meter measurements via scope BNC inputs in four channel model
• Connect-and-View™ triggering for intelligent, automatic triggering on fast, slow and even complex signals
• Frequency spectrum using FFT-analysis
• High-resolution, non-interlaced video
• Smart averaging
• ScopeRecord roll mode gives 30,000 points per input channel and capture waveform sample data for up to 48 hours
• TrendPlot, trend measurement readings for up to 22 days
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• Two USB ports make it easy to transfer data to a PC and store unlimited waveforms, screen captures and instrument setups on USB memory devices
• New high-perfomance Li-ion battery technology delivers the longest battery life on the market
• Charge spare battery using optional external battery charger
• Easy-access battery door for quick swaps in the field
• Security slot locks down oscilloscope with Kensington lock while unattended
• Environmentally tested to meet IP-51 and withstand 3 g vibration or 30 g shock
Specifications | |
Vertical Deflection | |
Number Of Channels | 2 |
Bandwidth | 200MHz |
Rise time | 1.7ns |
Number of scope inputs | 2 input channels plus external trigger |
Channel architecture | All inputs fully insulated from each other and from ground Inputs may be activated in any combination |
Input coupling | AC or DC, with ground level indicator |
Input sensitivity | 2 mV/div to 100 V/div, plus variable attenuation |
Bandwidth limiter | User selectable: 20 kHz, 20 MHz or full bandwidth |
Normal/invert/variable | On each input channel, switched separately |
Extended offset | Not avalable currently |
Input voltage | CAT III 1000 V/CAT IV 600 V rated, see general specifications for further details |
Vertical resolution | 8 bit |
Accuracy | ± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div |
Input impedance | 1 MΩ ± 1 %/14 pF ± 2 pF |
Horizontal | |
Maximum real-time sample rate (sampled simultaneously) | 2.5 GS/s (2ch) |
Record length | Up to 10,000 samples per channel |
Time base range | 2 ns/div to 4 s/div |
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord™ roll mode (see recorder mode) | |
Maximum record length | 10,000 samples per channel in scope mode |
30,000 points per channel in ScopeRecord™ roll mode (see recorder mode) | |
Timing accuracy | ± (0.01 % of reading + 1 pixel) |
Glitch capture | 8 ns peak detect on each channel (using real time sampling and data compression, at any timebase setting) |