Fluke 116/322 True RMS HVAC Multimeter & Clamp Meter Kit

$295.00
Availability: Out of stock
SKU
10H17

Condition: Refurbished

Warranty: 90 Day Exchange

Shipping: USA & Worldwide

Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

  • Fluke 116 HVAC True RMS Multimeter (BC# 26071)
  • Fluke 322 Clamp Meter w/ Instruction Card (BC# 26072)
  • (2) Fluke 1000V Hard Point Test Leads
  • (2) Fluke Flexible Test Leads
  • (2) Fluke Test Pins
  • Fluke P/N: 2559339 Cable For Clamp Meter w/ Adapter
  • Hard Copy User Manual
  • Carrying Case w/ Strap
Fluke 116/322 HVAC Multimeter And Clamp Meter Combo Kit
For the complete solution to HVAC troubleshooting, the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.


116 Specifications:
General specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] )
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Operating temperature -10 °C to + 50 °C
Storage temperature -40 °C to + 60 °C
Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life 400 hours typical, without backlight
 
Accuracy specifications
Measurement Range Resolution Accuracy
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2

DC volts
6.000 V 0.001 V
0.5 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz


AC volts true-rms
6.000 V 0.001 V
1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
60.00 V 0.01 V
600.0 V 0.1 V
Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects opens or shorts of 500 µs or longer




Ohms
600.0 Ω 0.1Ω 0.9 % + 2
6.000 kΩ 0.001 kΩ


0.9 % + 1
60.00 kΩ 0.01 kΩ
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
40.00 MΩ 0.01 MΩ
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF 1 nF 1.9 % + 2
10.00 µF 0.01 µF
100.0 µF 0.1 µF
9999 µF 1 µF
100 µF to 1000 µF 1.9 % + 2
> 1000 µF 5 % + 20
Lo-Z capacitance 1 nF to 500 µF 10 % + 2 typical
Temperature (Type-K thermocouple) -40 °C to 400 °C 0.1 °C 1 % + 10
-40 °F to 752 °F 0.2 °F 1 % + 18
AC µamps true-rms (45 Hz to 500 Hz) 600.0 µA 0.1 µA 1.5 % + 3 (2.5 % + 3 > 500 Hz)
DC µamps 600.0 µA 0.1 µA 1.0 % + 2


Hz (V or A input)
99.99 Hz 0.01 Hz

0.1 % + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz



322 Specifications
A Range 0 – 400 V
400 – 600 V
Accuracy 1.8 % ± 5 counts (50 Hz- 60 Hz) 3.0 % ± 5 counts (60 Hz - 400 Hz)
AC response Averaging
V Range 0 – 400 V
400 – 600 V
Accuracy 1.2 % + 5 counts (50 Hz - 400 Hz)
AC response Averaging
V Range 0 – 400 V 400 – 600 V
Accuracy 1 % ± 5 counts
? Range 0 – 400.0 ?
Accuracy 1 % ± 5 counts
Continuity ≤ 30 ?
Display hold Yes
Size Height 7.5”
Width 2.5”
Depth 1.4”
Jaw opening 1” (26 mm)
Max. wire size 500 MCM
Weight 8 oz.




For full FLuke 116 specifications, please click here: Fluke 116